12 17.5 24kV Torri Cylched Gwactod Dan Do, Cyfres GPVN-E
Cyflwr Amgylchynol
Tymheredd amgylchynol: -25 ℃ ~ + 45 ℃, cyfartaledd dyddiol: ≤35 ℃
Uchder: 1000m (Safonol);gall hyd at 4500m ar gyfer archebu arbennig;
Lleithder cymharol: cyfartaledd dyddiol ≤95%, cyfartaledd misol ≤90%;
Dwysedd daeargryn ≤8 gradd;
Dylai achlysuron perthnasol fod yn rhydd rhag inflamables, ffrwydron, cyrydol a dirgryniad difrifol.
Model
GPVN -12Kv/17.5kV Torri Cylched Gwactod Foltedd Uchel Dan Do
Manylebau Technegol
Nac ydw. | Eitem | Uned | Data | ||||||
1 | Foltedd graddedig | kV | 7.2~12(15/17.5) | ||||||
2 | Amledd graddedig | Hz | 50/60 | ||||||
3 | Cerrynt graddedig | A | 630,1000,1250 | 1600 | 2000,2500,3150 | 4000 | |||
4 | Cerrynt torri cylched byr graddedig | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
5 | Cerrynt gwneud cylched byr graddedig | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
6 | Amser byr graddedig gwrthsefyll cerrynt | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
7 | Uchafbwynt graddedig gwrthsefyll cerrynt | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
8 | Cerrynt torri allan graddedig | kA | 12.6 | 12.6 | 16 | 16 | 20 | ||
9 | Cerrynt torri ffawt daearu allan-o-gyfnod graddedig | kA | 17.4 | 21.7 | 27.4 | 27.4 | 34.7 | 34.7 | 43.5 |
10 | Amser torri cyfredol torri cylched byr graddedig | Amseroedd | 50 | 30 | 30 | 12 | |||
11 | Dilyniant gweithrediad graddedig | O-0.3s-CO-180s-CO | O-180au-CO-180au-CO | ||||||
12 | Cerrynt torri graddedig o fanc cynhwysydd sengl | A | 630 | ||||||
13 | Cerrynt torri graddedig o fanc cynhwysydd cefn wrth gefn | A | 400 | ||||||
14 | 1 mun.Amledd pŵer wrthsefyll foltedd | kV | O gam i gam/ i'r ddaear: 42, ar draws cysylltiadau agored:48 | ||||||
15 | Mae ysgogiad mellt yn gwrthsefyll foltedd | kV | O gam i gam/ i'r ddaear: 75, ar draws cysylltiadau agored:85 | ||||||
16 | Bywyd mecanyddol | Amseroedd | 20000 | ||||||
17 | Amser cau | ms | ≤75 | ||||||
18 | Amser agor | ms | ≤60 | ||||||
19 | Amser storio pŵer o dan foltedd graddedig | s | ≤10 |
Dimensiwn Amlinellol GPVN-12E
GPVN-24□ Torri Cylched Gwactod Foltedd Uchel AC Dan Do
Manyleb Technegol
Nac ydw. | Eitem | Uned | Data | |||
1 | Foltedd graddedig | kV | 24 | |||
2 | Amledd graddedig | Hz | 50/60 | |||
3 | Cerrynt graddedig | A | 630 1250 1600 2000 2500 3150 4000 | |||
4 | Cerrynt torri cylched byr graddedig | kA | 20 | 25 | 31.5 | 31.5 |
5 | Cerrynt gwneud cylched byr graddedig | kA | 50 | 63 | 80 | 80 |
6 | Cylched byr â sgôr yn gwrthsefyll cerrynt (4s) | kA | 20 | 25 | 31.5 | 31.5 |
7 | Uchafbwynt graddedig gwrthsefyll cerrynt | kA | 50 | 63 | 80 | 80 |
8 | Cerrynt torri allan-o-gam graddedig | kA |
|
| 12.6 | 12.6 |
9 | Cerrynt torri graddedig o fai daear y tu allan i'r cyfnod | kA | 17.4 | 21.7 | 27.4 | 27.4 |
10 | Amser torri graddedig o gerrynt torri cylched byr | Amseroedd | 50 | |||
11 | Dilyniant gweithredu graddedig |
| O-0.3s-CO-180s-CO | |||
12 | Cerrynt torri graddedig o fanc cynhwysydd sengl | A | 630 | |||
13 | Cerrynt torri graddedig o fanc cynhwysydd cefn wrth gefn | A | 400 | |||
14 | 1 mun.Amledd pŵer wrthsefyll foltedd | kV | 50 | |||
15 | Mae ysgogiad mellt yn gwrthsefyll foltedd | kV | 125 | |||
16 | Bywyd mecanyddol | Amseroedd | 20000 | |||
17 | Amser cau | ms | 75 | |||
18 | Amser agor | ms | 60 | |||
19 | Amser storio o dan foltedd graddedig | s | 10 |